Remote cathodic protection monitoring, from the people who design CP.
ICPM is a remote monitoring service developed by MCPL, a UK cathodic protection and corrosion engineering company.
Who is behind ICPM
MCPL (Materials and Corrosion Protection Limited) is a UK engineering company working in corrosion protection, materials engineering and cathodic protection, with a focus on oil and gas assets such as onshore pipelines, plants, jetties and tank farms. CP remote monitoring is one of its service lines, and ICPM is the monitoring unit and dashboard that supports it.
This page is about the monitoring service. For MCPL’s full range of services, company details and contacts, visit mcpl.uk.
What remote monitoring gives a CP engineer
A test-post survey tells you the state of protection on the day you were there. Remote readings fill in the time between visits and build a continuous record that both people and software can work from.
- Fewer routine visits. Potentials at difficult or distant test posts arrive without a trip, so site time can go where a reading shows it is needed.
- Earlier fault detection. A transformer-rectifier outage, a failed connection or a change in a coupon reading shows up as a change in the trend, not at the next annual survey.
- Seasonal and long-term context. Soil moisture, temperature and loading change potentials through the year. A record over time separates normal variation from a real problem.
- Records for compliance and audit. Dated readings held online give a consistent history to refer to when demonstrating how protection has been maintained.
- Safer work. Fewer journeys to remote, roadside or hazardous locations means less exposure for your people.
- Data that systems can use. Every reading arrives time-stamped, from a known asset and location, in a consistent format. That is the groundwork for automated alarms, asset-management dashboards and AI-assisted analysis, and for moving CP work from fixed survey rounds towards decisions driven by the data itself.
Where it is used
The same measurements apply across buried and immersed steel. The challenges differ by asset. These notes are general; each installation needs engineering judgement on where and how to monitor.
Gas and oil pipelines
Challenge: long routes, remote test posts and many rectifiers to keep running, with coating defects that develop slowly.
Remote readings: confirm that protection is continuing between surveys, flag a lost rectifier output promptly, and show gradual drift that points to coating damage.
Water and wastewater mains
Challenge: buried metallic mains in built-up areas where excavation and traffic management are costly.
Remote readings: a view of protection at key points without opening the road or entering a chamber, and a record of how it changes after nearby works.
District heating
Challenge: buried steel networks across urban areas, with many access points of varying convenience.
Remote readings: regular potentials from locations that are awkward to schedule, so changes can be followed without repeated visits.
Storage tanks and tank farms
Challenge: protection of tank bases and buried pipework within secured, sometimes hazardous areas.
Remote readings: routine readings taken and reported without a person entering the area each time, with data kept for inspection records.
Jetties and port structures
Challenge: exposed, tidal locations where access is weather dependent and sometimes unsafe.
Remote readings: a continuing record from accessible monitoring points, and earlier notice that a system needs attention.
Reinforced concrete
Challenge: protection of reinforcement that is hidden and slow to respond to changes.
Remote readings: trends that show whether protection is stable over months and years, where single spot readings can mislead.
Assets near power lines and railways
Challenge: induced AC from high-voltage lines, and stray current from electrified railways, which can vary hour to hour and are easy to miss in a one-off survey.
Remote readings: AC and DC potentials on the pipe and on a foreign structure, recorded on a schedule, so interference can be identified and followed.
What ICPM measures
A battery-powered unit at the test post, reporting to an online dashboard.
Measure
On a schedule the unit reads pipe, coupon and foreign-structure potentials, both DC and AC, plus coupon current, including the coupon instant-off potential.
Send
Readings go over the mobile network on an encrypted connection, then the unit powers down until the next reading.
Review
Sign in to the dashboard to see the latest values, the trend over time, and whether the coupon meets the −0.85 V protection criterion.
Full figures are in the specification on the home page.
Talk to us about your assets
Tell us what you are protecting and where the difficulties are. We can show you a live unit reporting to the dashboard.
info@mcpl.co.uk